BN3000 Input Metered PDU: (36)C13, (6)C19 11kVA (SLAVE)
Measurement per phase, network-capable and multifunctional
The BN3000 is an intelligent PDU. As with the BN2000, it enables measurements for each phase at PDU level via the network. It is also equipped with additional intelligent functions, therefore enabling professional energy and capacity management. Thanks to its compact design (1U), installing the BN3000 is flexible and space-saving, and enables optimised cabling and air flow in the server rack. Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface.
Furthermore, the BN3000 can be integrated into corresponding software systems via SNMP or Modbus TCP, for example.
Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.
This PDU is available as a 19” version or for vertical installation.
Further product configurations available on request.
Measurement per phase, network-capable and multifunctional
The BN3000 is an intelligent PDU. As with the BN2000, it enables measurements for each phase at PDU level via the network. It is also equipped with additional intelligent functions, therefore enabling professional energy and capacity management. Thanks to its compact design (1U), installing the BN3000 is flexible and space-saving, and enables optimised cabling and air flow in the server rack. Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface.
Furthermore, the BN3000 can be integrated into corresponding software systems via SNMP or Modbus TCP, for example.
Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.
This PDU is available as a 19” version or for vertical installation.
Further product configurations available on request.
Measurement per phase, network-capable and multifunctional
The BN3000 is an intelligent PDU. As with the BN2000, it enables measurements for each phase at PDU level via the network. It is also equipped with additional intelligent functions, therefore enabling professional energy and capacity management. Thanks to its compact design (1U), installing the BN3000 is flexible and space-saving, and enables optimised cabling and air flow in the server rack. Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface.
Furthermore, the BN3000 can be integrated into corresponding software systems via SNMP or Modbus TCP, for example.
Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.
This PDU is available as a 19” version or for vertical installation.
Further product configurations available on request.
-
The following measurement values are displayed per phase on the illuminated display and in the integrated web server:
Voltage [V]
Frequency [Hz]
Active power [kW]
Reactive power [kVAr]
Apparent power [kVA]
Active energy [kWh]
Reactive energy [kVArh]
Apparent energy [kVAh]
Power factor
-
Residual Current Monitoring (RCM type B) AC [mA] and DC [mA]
Surge Protection Device (SPD)
GPIO module
Housing colour
Temperature and air humidity sensors
-
Measurement per phase via network
Display with rotatable screen
Optional technology modules such as RCM type B
Cost benefit through Master/Slave cascading
A large number of protocols and interfaces supported
BN3000 (230-400 V / 50 Hz) Including Mounting Bracket
MODEL # | AMPS | PHASE(S) | OUTLET COUNT | OUTLET CONFIG | INPUT PLUG | POWER KVA | INPUT VOLTAGE | FIXING POSITION | PDU HEIGHT | RCM or SLAVE |
16 A / 230 V | ||||||||||
329.3164 | 13A | 1 | 5 | (5)BS1363 | BS1363 | 3kVA | 230V | Horizontal | 440x44x47mm | - |
802.3041 | 16A | 1 | 28 | (24)C13, (4)C19 | IEC60309 316P6 | 3.68kVA | 230V | Vertical | 1533x44x65mm | - |
16 A / 230 V / Residual Current Monitoring per supply cable | ||||||||||
802.3055 | 16A | 1 | 20 | (16)C13, (4)C19 | IEC60309 316P6 | 3.68kVA | 230V | Vertical | 1103x44x65mm | - |
802.3055-S | 16A | 1 | 20 | (16)C13, (4)C19 | IEC60309 316P6 | 3.68kVA | 230V | Vertical | 1103x44x65mm | SLAVE |
16 A / 400 V | ||||||||||
802.3012 | 16A | 3 | 30 | (24)C13, (6)C19 | IEC60309 516P6 | 11kVA | 415V | Vertical | 1533x44x65mm | - |
802.3012-S | 16A | 3 | 30 | (24)C13, (6)C19 | IEC60309 516P6 | 11kVA | 415V | Vertical | 1533x44x65mm | SLAVE |
16 A / 400 V / Residual Current Monitoring per supply cable | ||||||||||
802.3030 | 16A | 3 | 36 | (36)C13, (6)C19 | IEC60309 516P6 | 11kVA | 415V | Vertical | 1762x44x65mm | - |
802.3030-S | 16A | 3 | 36 | (36)C13, (6)C19 | IEC60309 516P6 | 11kVA | 415V | Vertical | 1762x44x65mm | SLAVE |
32 A / 230 V | ||||||||||
802.3005 | 32A | 1 | 20 | (16)C13, (4)C19 | IEC60309 332P6 | 7.68kVA | 230V | Vertical | 1762x44x65mm | - |
32 A / 400 V | ||||||||||
802.3013 | 32A | 3 | 30 | (24)C13, (6)C19 | IEC60309 532P6 | 22kVA | 415V | Vertical | 1762x44x65mm | - |
802.3013-S | 32A | 3 | 30 | (24)C13, (6)C19 | IEC60309 532P6 | 22kVA | 415V | Vertical | 1762x44x65mm | SLAVE |