BN3000 Input Metered PDU: (16)C13, (4)C19 3.68kVA (1103x44x65mm SLAVE)

€1,024.50

Measurement per phase, network-capable and multifunctional

The BN3000 is an intelligent PDU. As with the BN2000, it enables measurements for each phase at PDU level via the network. It is also equipped with additional intelligent functions, therefore enabling professional energy and capacity management. Thanks to its compact design (1U), installing the BN3000 is flexible and space-saving, and enables optimised cabling and air flow in the server rack. Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. 

Furthermore, the BN3000 can be integrated into corresponding software systems via SNMP or Modbus TCP, for example. 

Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.

This PDU is available as a 19” version or for vertical installation.

Further product configurations available on request.

Quantity:
Add To Cart

Measurement per phase, network-capable and multifunctional

The BN3000 is an intelligent PDU. As with the BN2000, it enables measurements for each phase at PDU level via the network. It is also equipped with additional intelligent functions, therefore enabling professional energy and capacity management. Thanks to its compact design (1U), installing the BN3000 is flexible and space-saving, and enables optimised cabling and air flow in the server rack. Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. 

Furthermore, the BN3000 can be integrated into corresponding software systems via SNMP or Modbus TCP, for example. 

Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.

This PDU is available as a 19” version or for vertical installation.

Further product configurations available on request.

Measurement per phase, network-capable and multifunctional

The BN3000 is an intelligent PDU. As with the BN2000, it enables measurements for each phase at PDU level via the network. It is also equipped with additional intelligent functions, therefore enabling professional energy and capacity management. Thanks to its compact design (1U), installing the BN3000 is flexible and space-saving, and enables optimised cabling and air flow in the server rack. Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. 

Furthermore, the BN3000 can be integrated into corresponding software systems via SNMP or Modbus TCP, for example. 

Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.

This PDU is available as a 19” version or for vertical installation.

Further product configurations available on request.

  • The following measurement values are displayed per phase on the illuminated display and in the integrated web server:

    • Voltage [V]

    • Frequency [Hz]

    • Active power [kW]

    • Reactive power [kVAr]

    • Apparent power [kVA]

    • Active energy [kWh]

    • Reactive energy [kVArh]

    • Apparent energy [kVAh]

    • Power factor

    • Residual Current Monitoring (RCM type B) AC [mA] and DC [mA]

    • Surge Protection Device (SPD)

    • GPIO module

    • Housing colour

    • Temperature and air humidity sensors

    • Measurement per phase via network

    • Display with rotatable screen

    • Optional technology modules such as RCM type B

    • Cost benefit through Master/Slave cascading

    • A large number of protocols and interfaces supported

BN3000 (230-400 V / 50 Hz) Including Mounting Bracket

MODEL # AMPS PHASE(S) OUTLET COUNT OUTLET CONFIG INPUT PLUG POWER KVA INPUT VOLTAGE FIXING POSITION PDU HEIGHT RCM or SLAVE
16 A / 230 V
329.3164 13A 1 5 (5)BS1363 BS1363 3kVA 230V Horizontal 440x44x47mm -
802.3041 16A 1 28 (24)C13, (4)C19 IEC60309 316P6 3.68kVA 230V Vertical 1533x44x65mm -
16 A / 230 V / Residual Current Monitoring per supply cable
802.3055 16A 1 20 (16)C13, (4)C19 IEC60309 316P6 3.68kVA 230V Vertical 1103x44x65mm -
802.3055-S 16A 1 20 (16)C13, (4)C19 IEC60309 316P6 3.68kVA 230V Vertical 1103x44x65mm SLAVE
16 A / 400 V
802.3012 16A 3 30 (24)C13, (6)C19 IEC60309 516P6 11kVA 415V Vertical 1533x44x65mm -
802.3012-S 16A 3 30 (24)C13, (6)C19 IEC60309 516P6 11kVA 415V Vertical 1533x44x65mm SLAVE
16 A / 400 V / Residual Current Monitoring per supply cable
802.3030 16A 3 36 (36)C13, (6)C19 IEC60309 516P6 11kVA 415V Vertical 1762x44x65mm -
802.3030-S 16A 3 36 (36)C13, (6)C19 IEC60309 516P6 11kVA 415V Vertical 1762x44x65mm SLAVE
32 A / 230 V
802.3005 32A 1 20 (16)C13, (4)C19 IEC60309 332P6 7.68kVA 230V Vertical 1762x44x65mm -
32 A / 400 V
802.3013 32A 3 30 (24)C13, (6)C19 IEC60309 532P6 22kVA 415V Vertical 1762x44x65mm -
802.3013-S 32A 3 30 (24)C13, (6)C19 IEC60309 532P6 22kVA 415V Vertical 1762x44x65mm SLAVE
 
BN3000 Input Metered PDU: (24)C13, (6)C19 22kVA (SLAVE)
€1,236.95
BN3000 Input Metered PDU: (16)C13, (4)C19 3.68kVA (1103x44x65mm)
€1,070.95
BN3000 Input Metered PDU: (24)C13, (4)C19 3.68kVA
€965.50
BN3000 Input Metered PDU: (16)C13, (4)C19 7.68kVA
€1,062.95
BN3000 Input Metered PDU: (24)C13, (6)C19 11kVA (SLAVE)
€894.50