BN7000 Switched Outlet PDU: (24)C13, (6)C19 22kVA
Measurement per phase, switchable outlets, network-capable and multifunctional.
The BN7000 is an intelligent PDU. As with the BN3000, it enables professional energy and capacity management through network-capable measurements for each phase at PDU level. In addition, the outlets can be switched individually.
Thanks to its compact design (1U), installing the BN7000 is flexible and space-saving, and therefore enables optimised cabling and air flow in the server rack. Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. Furthermore, the BN7000 can be integrated into third-party software systems via SNMP or Modbus TCP, for example.
Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.
Furthermore, the flexible design of the PDU and different technology modules make a multitude of customised versions possible.
This PDU is available as a 19” version or for vertical installation.
Further product configurations available on request.
Measurement per phase, switchable outlets, network-capable and multifunctional.
The BN7000 is an intelligent PDU. As with the BN3000, it enables professional energy and capacity management through network-capable measurements for each phase at PDU level. In addition, the outlets can be switched individually.
Thanks to its compact design (1U), installing the BN7000 is flexible and space-saving, and therefore enables optimised cabling and air flow in the server rack. Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. Furthermore, the BN7000 can be integrated into third-party software systems via SNMP or Modbus TCP, for example.
Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.
Furthermore, the flexible design of the PDU and different technology modules make a multitude of customised versions possible.
This PDU is available as a 19” version or for vertical installation.
Further product configurations available on request.
Measurement per phase, switchable outlets, network-capable and multifunctional.
The BN7000 is an intelligent PDU. As with the BN3000, it enables professional energy and capacity management through network-capable measurements for each phase at PDU level. In addition, the outlets can be switched individually.
Thanks to its compact design (1U), installing the BN7000 is flexible and space-saving, and therefore enables optimised cabling and air flow in the server rack. Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. Furthermore, the BN7000 can be integrated into third-party software systems via SNMP or Modbus TCP, for example.
Granular measurement recording accompanied by neutral conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.
Furthermore, the flexible design of the PDU and different technology modules make a multitude of customised versions possible.
This PDU is available as a 19” version or for vertical installation.
Further product configurations available on request.
-
The following measurement values are displayed for each phase and outlet on the illuminated display, as well as in the integrated web server:
Current [A]
Neutral conductor current [A] for three-phase versions
Voltage [V]
Frequency [Hz]
Active power [kW]
Reactive power [kVAr]
Apparent power [kVA]
Active energy [kWh]
Reactive energy [kVArh]
Apparent energy [kVAh]
Power factor
-
Residual Current Monitoring (RCM type B) AC [mA] and DC [mA]
Surge Protection Device (SPD)
GPIO module
Housing colour
Temperature and air humidity sensors
-
Measurement per phase – switchable outlets
Display with rotatable screen
Optional technology modules such as RCM type B
Cost benefit through Master/Slave cascading
A large number of protocols and interfaces supported
BN7000 (230-400 V / 50 Hz) INCLUDING MOUNTING KIT
MODEL # | AMPS | PHASE(S) | OUTLET COUNT | OUTLET CONFIG | INPUT PLUG | POWER KVA | INPUT VOLTAGE | FIXING POSITION | PDU HEIGHT | RCM or SLAVE |
16 A / 230 V | ||||||||||
802.7000 | 16A | 1 | 22 | (18)C13, (4)C19 | IEC60309 316P6 | 3.68kVA | 230V | Horizontal | 1234x44x65mm | - |
802.7000-S | 16A | 1 | 22 | (18)C13, (4)C19 | IEC60309 316P6 | 3.68kVA | 230V | Horizontal | 1234x44x65mm | SLAVE |
802.7021 | 16A | 1 | 28 | (24)C13, (4)C19 | IEC60309 316P6 | 3.68kVA | 230V | Horizontal | 1533x44x65mm | - |
16 A / 230 V | ||||||||||
802.7014 | 16A | 1 | 42 | (36)C13, (6)C19 | IEC60309 316P6 | 3.68kVA | 230V | Horizontal | 1943x44x65mm | - |
802.7008 | 16A | 1 | 30 | (24)C13, (6)C19 | IEC60309 316P6 | 3.68kVA | 230V | Horizontal | 1762x44x65mm | - |
802.7008-S | 16A | 1 | 30 | (24)C13, (6)C19 | IEC60309 316P6 | 3.68kVA | 230V | Horizontal | 1762x44x65mm | SLAVE |
16 A / 400 V / Residual Current Monitoring per phase | ||||||||||
802.7026 | 16A | 3 | 30 | (24)C13, (6)C19 | IEC60309 516P6 | 11kVA | 415V | Horizontal | 1762x44x65mm | - |
32 A / 230 V | ||||||||||
802.7001 | 32A | 1 | 20 | (16)C13, (4)C19 | IEC60309 332P6 | 7.68kVA | 230V | Horizontal | 1234x44x65mm | - |
802.7022 | 32A | 1 | 28 | (24)C13, (4)C19 | IEC60309 332P6 | 7.68kVA | 230V | Horizontal | 1533x44x65mm | - |
32 A / 400 V | ||||||||||
802.7009 | 32A | 3 | 30 | (24)C13, (6)C19 | IEC60309 532P6 | 22kVA | 415V | Horizontal | 1762x44x65mm | - |