BN3000 Inline Metered PDU: (1)in, (1) out 3.68kVA

€844.50

Measurement per phase, network-capable and multifunctional.

The BN3000 Inline is the ideal intermediary retrofit solution for equipping existing installations in data centres with the functions of the BN3000 at a later date. The BN3000 Inline enables professional energy and capacity management through network-capable measurements per phase at PDU level.

Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. Furthermore, the BN3000 can be integrated into corresponding software systems via SNMP or Modbus TCP, for example. Granular measurement accompanied by neutral-conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.

This PDU is available as a 19” version or for vertical installation.

Further product configurations available on request.

Quantity:
Add To Cart

Measurement per phase, network-capable and multifunctional.

The BN3000 Inline is the ideal intermediary retrofit solution for equipping existing installations in data centres with the functions of the BN3000 at a later date. The BN3000 Inline enables professional energy and capacity management through network-capable measurements per phase at PDU level.

Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. Furthermore, the BN3000 can be integrated into corresponding software systems via SNMP or Modbus TCP, for example. Granular measurement accompanied by neutral-conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.

This PDU is available as a 19” version or for vertical installation.

Further product configurations available on request.

Measurement per phase, network-capable and multifunctional.

The BN3000 Inline is the ideal intermediary retrofit solution for equipping existing installations in data centres with the functions of the BN3000 at a later date. The BN3000 Inline enables professional energy and capacity management through network-capable measurements per phase at PDU level.

Whether on-site or remotely via Ethernet: energy consumption measurements can be viewed locally on the display or via the web server using the clear and highly functional software interface. Furthermore, the BN3000 can be integrated into corresponding software systems via SNMP or Modbus TCP, for example. Granular measurement accompanied by neutral-conductor monitoring and RCM type B (as an option) ensures maximum safety in the data centre. In addition, intelligent Master/Slave cascading in the PDU network enables cost-optimised network management.

This PDU is available as a 19” version or for vertical installation.

Further product configurations available on request.

  • The following measurement values are displayed for each phase on the backlit display and in the integrated web server:

    • Current [A]

    • Neutral conductor current [A] in three-phase versions |

    • Voltage [V]

    • Frequency [HZ]

    • Active power [kW]

    • Reactive power [kVar]

    • Apparent power [kVA]

    • Active energy [kWh]

    • Reactive energy [kVarh]

    • Apparent energy [kVAh]

    • Power factor

    • Residual current measurement (RCM type B) AC [mA] and DC [mA]

    • Surge protection (SPD)

    • GPIO module

    • Housing colour

    • Measurement per phase

    • Display with rotatable screen

    • Optional technology modules such as RCM type B

    • Cost benefit through master/slave cascading

    • A large number of protocols and interfaces supported

BN3000 (230-400 V / 50 Hz) Including Mounting Bracket

• Power input: 3.0 m H05VV-F with CEE plug

• Power output: 3.0 m H05VV-F with CEE coupling

MODEL # AMPS PHASE(S) OUTLET COUNT OUTLET CONFIG INPUT PLUG POWER KVA INPUT VOLTAGE FIXING POSITION PDU HEIGHT
16 A / 230 V
802.3069 16A 1 - (1)in, (1) out IEC60309 316P6 3.68kVA 230V Horizontal 440x44x47mm
16 A / 400 V
802.3067 16A 1 - (1)in, (1) out IEC60309 332P6 7.40kVA 230V Horizontal 440x44x47mm
32 A / 230 V
802.3070 32A 3 - (1)in, (1) out IEC60309 516P6 11kVA 415V Horizontal 440x44x47mm
32 A / 400 V
802.3068 32A 3 - (1)in, (1) out IEC60309 532P6 22kVA 415V Horizontal 440x44x47mm
 
BN3000 Inline Metered PDU: (1)in, (1) out 22kVA
€954.50
BN3000 Inline Metered PDU: (1)in, (1) out 11kVA
€993.95
BN3000 Inline Metered PDU: (1)in, (1) out 7.40kVA
€985.95